01622 882 400CONTACT US
0item(s)

You have no items in your shopping cart.

Product was successfully added to your shopping cart.

Wilo-Stratos-D

Be the first to review this product

Quick Overview

Glandless double circulation pump suitable for: hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems.

Download Technical Sheet for Wilo-Stratos-D PDF

Download Wilo-Stratos -D Installation and Operating Instructions pdf

Product Name Price Qty

Wilo-Stratos-D

Wilo-STRATOS-D 32/1-8 PN6/10 2160567
Excl. Tax: £811.20 Incl. Tax: £973.44

Wilo-Stratos-D

Wilo-STRATOS-D 32/1-12 PN6/10 (DE) 2090462
Excl. Tax: £1,176.00 Incl. Tax: £1,411.20

Wilo-Stratos-D

Wilo STRATOS-D 40/1-8 PN6/10 2090463
Excl. Tax: £1,027.20 Incl. Tax: £1,232.64

Wilo-Stratos-D

Wilo-STRATOS-D 40/1-12 PN6/10 2090464
Excl. Tax: £1,480.20 Incl. Tax: £1,776.24

Wilo-Stratos-D

Wilo STRATOS-D 50/1-8 PN6/10 2090465
Excl. Tax: £1,659.00 Incl. Tax: £1,990.80

Wilo-Stratos-D

Wilo-STRATOS-D 50/1-9 PN6/10 2090466
Excl. Tax: £2,157.60 Incl. Tax: £2,589.12

Wilo-Stratos-D

Wilo-STRATOS-D 50/1-12 PN6/10 2090467
Excl. Tax: £2,380.80 Incl. Tax: £2,856.96

Wilo-Stratos-D

Wilo-STRATOS-D 65/1-12 PN6/10 2160571
Excl. Tax: £2,404.80 Incl. Tax: £2,885.76

Wilo-Stratos-D

Wilo-STRATOS-D 80/1-12 PN6 2150600
Excl. Tax: £2,470.20 Incl. Tax: £2,964.24

Wilo-Stratos-D

Wilo-STRATOS-D 80/1-12 PN10 2150601
Excl. Tax: £3,378.00 Incl. Tax: £4,053.60

Availability: In stock

Details

Wilo-Stratos-D

Glandless double circulation pump with flange connection, EC motor with automatic power adjustment

Application

Hot-water heating systems of all kinds, air-conditioning systems, closed cooling circuits, industrial circulation systems

Type key

Example: Stratos‐D 40/1-8
Stratos High-efficiency pump (flange-end pump), electronically controlled
D Double pump
40/ Nominal connection diameter
1-8 Nominal delivery head range [m]

Special features/product advantages

  • Energy efficiency class A
  • Highest degrees of efficiency due to ECM technology
  • Up to 80% electricity savings compared to uncontrolled circulation pumps
  • Front operation and access to the terminal space, variable installation positions, display independent of position
  • Simple installation due to combination flanges PN 6/PN 10 (with DN 32 to DN 65)
  • Can be used in cooling/air-conditioning systems without ambient temperature limits
  • Pump housing with cataphoretic (cataphoretic) coating for the prevention of corrosion by condensation formation
  • System expansion by means of retrofittable interface modules for communication: Modbus, BACnet, LON, CAN, PLR etc.
  • Remote operation via infrared interface (IR-Module/IR-Stick/IR-Monitor)
  • Integratable dual pump management due to retrofit Stratos IF-Modules:
    • Main/standby mode with fault-dependent switchover
    • Efficiency-optimised peak-load operation

Technical data

  • Permissible temperature range ‐-10°C to +110°C
  • Mains connection 1~230 V, 50/60 Hz
  • Protection class IP X4D
  • Flange connection DN 32 to DN 80
  • Max. operating pressure, standard version: 6/10 bar or 6 bar (special version: 10 bar or 16 bar)

Equipment/function

Operating modes

  • Manual control mode (n=constant)
  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • Δp-T for temperature-controlled differential pressure (programmable via IR-Module, IR-Stick, IR-Monitor, Modbus, BACnet, LON or CAN)

Manual functions

  • Operating mode setting
  • Differential-pressure setpoint setting
  • Setting automatic setback operation
  • Pump ON/OFF setting
  • Speed setting (manual control mode)

Automatic functions

  • Stageless power adjustment depending on the operating mode
  • Automatic setback operation
  • Deblocking function
  • Soft start
  • Full motor protection with integrated trip electronics

External control functions

  • "Overriding Off" control input (possible with Stratos IF-Modules)
  • "Overriding Min" control input (possible with Stratos IF-Modules)
  • "Analogue In 0 ‐ 10 V" control input (remote speed adjustment) (possible with Stratos IF-Modules)
  • "Analogue In 0 ‐ 10 V" control input (remote setpoint adjustment) (possible with Stratos IF-Modules)

Signal and display functions

  • Individual / collective fault signal (potential-free NC contact) (programmable with the IR-Module/IR-Stick/IR-Monitor)
  • Collective fault signal (potential-free NC contact)
  • Individual run signal (potential-free NO contact) (possible with Stratos IF-Modules)
  • Fault signal light
  • LC display for indication of pump data and fault codes

Data exchange

  • Infrared interface for wireless data exchange with IR-Module/IR-Stick/IR-Monitor
  • Serial digital interface Modbus RTU for connection to building automation BA via BUS system RS485 (possible with IF-Modules Stratos)
  • Serial digital interface BACnet MS/TP Slave for connection to building automation BA via BUS system RS485 (possible with IF-Modules Stratos)
  • Serial digital interface CAN for connection to building automation BA via BUS system CAN (possible with IF-Modules Stratos)
  • Serial digital LON interface for connection to a LONWorks network (possible with Stratos IF-Modules)
  • Serial digital PLR interface for connection to BA via Wilo interface converter or company-specific coupling modules (possible with Stratos IF-Modules)

Dual pump management (double pump or 2 x single pump)

  • Main/standby operation (automatic fault-actuated switchover/time-dependent pump cycling): Various combinations with Stratos IF-Modules (accessories) possible
  • Parallel operation (efficiency-optimised peak load activation and deactivation): Various combinations with Stratos IF-Modules (accessories) possible

Equipment

  • Flange versions:
    • Standard version for pumps DN 32 to DN 65: combination flange PN 6/10 (flange PN 16 according to EN 1092-2) for counter flanges PN 6 and PN 16,
    • Standard version for pumps DN 80: flange PN 6 (dimensioned PN 16 according to EN 1092-2) for counter flange PN 6,
    • Special version for pumps DN 32 to DN 80: Flange PN 16 (according to EN 1092-2) for counter flange PN 16,
  • double switchover valve in pump housing
  • Plug-in position for optional extension with Wilo-IF‐Modules

Materials

  • Pump housing: Grey cast iron
  • Shaft: stainless steel
  • Bearing: Carbon, metal impregnated
  • Impeller: Plastic

Scope of delivery

  • Pump
  • Incl. washers for flange screws (for nominal connection diameters DN 32 ‐ DN 65)
  • Including installation and operating instructions

Options

  • Special versions for operating pressure PN 16 (at additional charge)

Accessories

  • Blind flanges
  • IR-Module
  • IR-Stick
  • IR-Monitor
  • Stratos IF-Modules: Modbus, BACnet, CAN, PLR, LON, DP, Ext. Off, Ext. Min., SBM, Ext.Off/SBM

Additional Information

SKU Wilo-Stratos-D
GTIN N/A
MPN N/A
  1. Be the first to review this product

Write Your Own Review

Below are related articles that you may find helpful.

How to Read a Pump Curve (Blog Article)