01622 882 400CONTACT US
0item(s)

You have no items in your shopping cart.

ATAC Accreditations

Product was successfully added to your shopping cart.
Previous

Wilo Stratos PICO-Z

Previous

Wilo-VeroLine-IPL25-32

Wilo-Stratos-Z

Be the first to review this product

Quick Overview

Glandless circulating pump with screwed connection or flange connection, EC motor and automatic power adjustment.


Secondary hot water circulation systems of all kinds, hot-water heating systems of all kinds, air-conditioning, closed cooling circuits, industrial circulation systems

Product Name Price Qty

Wilo-Stratos-Z

Wilo-STRATOS-Z 25/1-8 RG 2090469
Excl. Tax: £577.50 Incl. Tax: £693.00

Wilo-Stratos-Z

Wilo-STRATOS-Z 30/1-12 PN6/10 2090471
Excl. Tax: £785.40 Incl. Tax: £942.48

Wilo-Stratos-Z

Wilo-STRATOS-Z 30/1-8 RG 2090470
Excl. Tax: £640.50 Incl. Tax: £768.60

Wilo-Stratos-Z

Wilo-STRATOS-Z 40/1-12 RG 2090473
Excl. Tax: £1,445.85 Incl. Tax: £1,735.02

Wilo-Stratos-Z

Wilo-STRATOS-Z 40/1-8 PN6/10 2090472
Excl. Tax: £1,207.50 Incl. Tax: £1,449.00

Wilo-Stratos-Z

Wilo-STRATOS-Z 50/1-9 RG (DE) num 2090474
Excl. Tax: £1,585.50 Incl. Tax: £1,902.60

Wilo-Stratos-Z

Wilo-STRATOS-Z 65/1-12 PN6/10 2152257
Excl. Tax: £1,653.75 Incl. Tax: £1,984.50

Availability: In stock

Details

Wilo-Stratos-Z

Glandless circulating pump with screwed connection or flange connection, EC motor and automatic power adjustment.

Application

Secondary hot water circulation systems of all kinds, hot-water heating systems of all kinds, air-conditioning, closed cooling circuits, industrial circulation systems

Type key

Example: Wilo-Stratos-Z 40/1-8
Stratos High-efficiency pump (screw-end or flange-end pump), electronically controlled
Z Single pump for secondary hot water circulation
40/ Nominal connection diameter
1-8 Nominal delivery head range [m]

Special features/product advantages

  • Highest degrees of efficiency due to ECM technology
  • Front operation and access to the terminal space, variable installation positions, display independent of position
  • Simple installation due to combination flanges PN 6/PN 10 (with DN 40 to DN 65)
  • Corrosion-resistant pump housing made of red brass for systems where oxygen entry is possible
  • Automatic adjustment of the pump output in secondary hot water circulation systems with variable volume flow with thermostatically controlling line shut-off valves
  • Manual control mode allows optimum adaptation of the pump output to the system in constant-volume secondary hot water circulation systems
  • System expansion by means of retrofittable interface modules for communication: Modbus, BACnet, LON, CAN, PLR etc.
  • Remote operation via infrared interface (IR-Module/IR-Stick/IR-Monitor)

Technical data

  • Permissible temperature range
    • Potable water up to 3.57 mmol/l (20 °dH): 0 °C to +80 °C
    • Heating water: ‐-10 °C to +110 °C
  • Mains connection 1~230 V, 50/60 Hz
  • Protection class IP X4D
  • Screwed connection or flange connection (depending on type) Rp 1 to DN 65
  • Max. operating pressure, standard version: 6/10 bar (special version: 16 bar)

Equipment/function

Operating modes

  • Manual control mode (n=constant)
  • Δp-c for constant differential pressure
  • Δp-v for variable differential pressure
  • Δp-T for temperature-controlled differential pressure (programmable via IR-Module, IR-Stick, IR-Monitor, Modbus, BACnet, LON or CAN)

Manual functions

  • Operating mode setting
  • Differential-pressure setpoint setting
  • Setting automatic setback operation
  • Pump ON/OFF setting
  • Speed setting (manual control mode)

Automatic functions

  • Stageless power adjustment depending on the operating mode
  • Automatic setback operation
  • Deblocking function
  • Soft start
  • Full motor protection with integrated trip electronics
External control functions
  • "Overriding Off" control input (possible with Stratos IF-Modules)
  • "Overriding Min" control input (possible with Stratos IF-Modules)
  • "Analogue In 0 ‐ 10 V" control input (remote speed adjustment) (possible with Stratos IF-Modules)
  • "Analogue In 0 ‐ 10 V" control input (remote setpoint adjustment) (possible with Stratos IF-Modules)

 

Signal and display functions
  • Collective fault signal (potential-free NC contact)
  • Individual run signal (potential-free NO contact) (possible with Stratos IF-Modules)
  • Fault signal light
  • LC display for indication of pump data and fault codes

Data exchange

  • Infrared interface for wireless data exchange with IR-Module/IR-Stick/IR-Monitor
  • Serial digital interface Modbus RTU for connection to building automation BA via BUS system RS485 (possible with IF-Modules Stratos)
  • Serial digital interface BACnet MS/TP Slave for connection to building automation BA via BUS system RS485 (possible with IF-Modules Stratos)
  • Serial digital interface CAN for connection to building automation BA via BUS system CAN (possible with IF-Modules Stratos)
  • Serial digital LON interface for connection to a LONWorks network (possible with Stratos IF-Modules)
  • Serial digital PLR interface for connection to BA via Wilo interface converter or company-specific coupling modules (possible with Stratos IF-Modules)

Dual pump management (double pump or 2 x single pump)

  • Main/standby mode (automatic fault-actuated switchover/time-dependent pump cycling): Various combinations with Stratos IF-Modules (accessories) possible
  • Parallel operation (efficiency-optimised peak load activation and deactivation): Various combinations with Stratos IF-Modules (accessories) possible

Equipment

  • Wrench attachment point on pump body (for threaded pipe union pumps with P2≤100 W)
  • In flange pumps: Flange versions
    • Standard version for pumps DN 40 to DN 65: combination flange PN 6/10 (flange PN 16 according to EN 1092-2) for counter flanges PN 6 and PN 16,
    • Special version for pumps DN 40 to DN 65: Flange PN 16 (according to EN 1092-2) for counter flange PN 16,
  • Plug-in position for optional extension with Wilo-IF‐Modules
  • Thermal insulation as standard

Materials

  • Pump housing made of red brass (30/1‐12 and 40/1‐8 types, also grey cast iron)
  • Impeller: Plastic
  • Shaft: stainless steel
  • Bearing: Carbon, synthetic resin impregnated

 Scope of delivery

  • Pump
  • Including thermal insulation
  • Including seals for threaded connection (loose)
  • Including washers for flange screws (for nominal connection diameters DN 40 ‐ DN 65)
  • Including installation and operating instructions

Options

  • Special versions for operating pressure PN 16 (at additional charge)

Accessories

  • Screwed connection for threaded connection
  • Adapter fittings
  • IR-Module
  • IR-Stick
  • IR-Monitor
  • Stratos IF-Modules: Modbus, BACnet, CAN, PLR, LON, DP, Ext. Off, Ext. Min., SBM, Ext.Off/SBM

 

Download Wilo-Stratos-Z Installation and operating instructions pdf

Additional Information

SKU Wilo-Stratos-Z
GTIN N/A
MPN N/A
  1. Be the first to review this product

Write Your Own Review

Below are related articles that you may find helpful.

How to Read a Pump Curve (Blog Article)